by uax50jo8

2011-12-6 16:36
Source: Beijing Chigo Air Conditioning Repair Phone http://blog.tianya.cn/blogger/blog_main.asp?BlogID=3482552. Fault Phenomenon: The outdoor unit does not sta......
2011-11-4 20:14
The indoor unit of the AUX split-type air conditioner is leaking. Fault phenomenon: During the drainage experiment, the water discharge from the outdoor unit's......
2011-10-29 12:1
Source: Beijing Zhigao Air Conditioning Repair Phone http://blog.tianya.cn/blogger/blog_main.asp?BlogID=3943975. Fault Phenomenon: The unit was mistakenly conn......
2011-10-29 11:40
Fault phenomenon: The unit was mistakenly connected to a 380V power supply, causing the entire machine to stop working. Analysis and maintenance: Upon disass......
2011-10-12 19:19
The Beijing AUX Air Conditioning Repair Center explains that a refrigeration compressor is a type of machine that increases gas pressure and plays the role of ......
2011-9-30 17:10
The thermal expansion valve, also known as a temperature-sensing expansion valve, has its temperature sensing bulb tightly attached to the outlet pipe of the e......
2011-9-17 15:55
The Beijing AUX air conditioner repair hotline provides analytical data. Analysis and inspection: For AUX air conditioners, the referenced fault code correspo......
2011-9-12 19:5
The indoor temperature does not drop after Gree air conditioner starts and runs for 2 hours in cooling mode. Analysis and Maintenance: The outdoor ambient te......
2011-9-4 9:52
Beijing LG Air Conditioning After-sales Service and Maintenance Center - edited and organized. Analysis and Inspection: The power supply voltage was measured ......
2011-9-1 14:38
Warm prompt: The overload protector is usually installed inside the compressor wiring box, with its open end tightly attached to the compressor shell to sense ......
2011-8-29 14:18
Repair method: Replace the same power compressor, troubleshoot. Gree inverter air conditioner, indoor unit works, outdoor unit does not work. Analysis and T......
2011-8-17 15:49
Oxford Air Conditioning Repair Q&A: How to Coordinate the Electric Meter Capacity with Air Conditioners The capacity of household electric meters is generall......
2011-8-14 16:52
AUX Air Conditioner Repair Guide: Not Cooling (Varistor ZNR1 Damaged) Analysis and Testing: After testing, it was found that the varistor ZNR1 on the circuit......
2011-8-11 14:20
Aux air conditioner,不定时出现死机 Model: KFR-25GW / G Fault phenomenon: Can't start with the remote control, but can cool normally using the emergency function. ......
2011-8-2 14:3
**Title: AUX Air Conditioner - High Noise from Indoor Unit** **Fault Phenomenon:** A KFRd-72LW air conditioner has high noise from the indoor unit. **Repair ......
2011-7-30 14:48
**Title: AOXI Air Conditioning - Repair Case; System Leakage Caused by Lack of Refrigerant** **Fault Phenomenon:** After running for a period of time, the air......