Q2 Siemens washing machine troubleshooting examples 1 I9

by fjk50kl8 on 2011-10-28 18:54:10

Beijing Siemens Washing Machine Repair Phone Number - Fault Diagnosis: Add a 0.52mm thick washer at the screw hole of the fixed protective cover on the base to increase the internal clearance; alternatively, the moving blade can be trimmed appropriately. Then check that the push contact is in good condition, perform an operational test, and if the washing machine works normally, the fault is resolved.

Siemens Washing Machine Complex Fault Diagnosis Example 1

Source: Beijing Siemens Washing Machine Repair Center http://blog.tianya.cn/blogger/blog_main.asp?BlogID=3432932.

Fault Analysis: When using a multimeter ohm range to measure the resistance between the live wire and neutral wire of the power cord plug through the start switch, no normal 4.5Ω DC resistance value for the water inlet solenoid valve coil or 40Ω resistance value for the drainage solenoid coil was detected. After removing the program controller's protective cover and conducting an operational test, the fault disappeared again, and the resistance values of both solenoid valves were measured as normal. The reason is that the external plastic lever for pushing the contacts does not have as large a movement amplitude as when the protective cover is removed, and the moving blade is not straight but curls upwards, causing it to rub against the inner wall of the housing and become obstructed, leading to inadequate contact of the points.

Fault Symptoms: During the wash cycle activation, the water inlet solenoid valve cannot open to allow water intake, and switching to the drainage cycle results in no response from the drainage electromagnet.