The main causes and fault phenomena of leakage in the Panasonic air conditioning refrigeration system
Panasonic Air Conditioning Repair Summary: For air conditioners that have been used for a long time, due to the corrosion of the refrigerant on the evaporator and pipes, coupled with pipe vibration and mutual friction causing cracks and holes, leakage occurs. For air conditioners installed within two years or newly installed, leaks are often caused by improper operation during installation or poor quality of the pipe joints,喇叭mouths, and seals used. A leak in the refrigeration system reduces the amount of refrigerant in the system, leading to a decrease in air conditioning cooling (heating). If all the refrigerant in the system leaks out, although the compressor is still working, it will completely fail to cool (heat).
Article source: http://blog.sina.com.cn/songxiakt