Ammonia exists in natural water resources and is also a product of microbial decomposition of proteins in decaying animals and plants. If the degree of ammonia concentration in surface water shows the extent of pollution of domestic water. Ammonia and its compounds are also used as fertilizers, VIC-711. Generally, the most ideal resolution will not be lower than 0.1mg/L, usually only 0.5mg/L. The Lovibond water quality analysis tester, according to international water quality testing standards, adopts microcomputer control technology, making measurements fast and accurate. The microcomputer concentration tester can measure one or more measurement items; with built-in measuring curves, reagents react with the samples to be measured, converting the absorbance of the sample for a specific wavelength into the concentration value of the parameter to be measured, and displaying the results of the sample through an LCD liquid crystal display. The sample cell adopts a sealed anti-pollution design, ensuring that there will be no pollution or damage to various precision components inside the instrument during the measurement process and daily management. Using specially designed patented LED light sources, stable light sources are provided at low energy consumption. User-friendly interface, TE412-L type precision balance, high-quality quality, excellent performance, simple and quick operation, and dual calibration functions of factory calibration and user-defined calibration, making the measurement accurate, stable, and reproducible.
The main performance features of the Lovibond microcomputer ammonia nitrogen analyzer:
? Lightweight and portable design, novel appearance, user-friendly interface, HI93748-03, simple and quick operation;
? Uses temperature-compensated LED light source, unique microcomputer control technology;
? Excellent multi-purpose application, suitable for both laboratory and field use;
? Factory calibration and user-defined calibration functions, waterproof sample pool for easy measurement and maintenance;
? Uses pre-made reagents, greatly saving your time, fast and accurate measurement;
? Easy-to-read display screen, good GLP function, built-in real-time clock, backlight display;
? Automatic power-off energy-saving mode;
ET6500 (Dual Range Ammonium Nitrogen) Specifications:
Range: 0.00 to 1.00 mg/L NH4+ 0.0 to 10.0 mg/L NH4+
Resolution: 0.01 mg/L 0.1 mg/L
Accuracy: ±2% of reading ± 0.002 mg/L
Wavelength Setting: 660 nm
Optical System: Waterproof sample cell, temperature-compensated LED optical system
Calibration Mode: Automatic zero correction, precision balance, using SMD microprocessor technology, dual calibration mode of factory calibration and user-defined calibration
GLP Function: Built-in real-time clock, backlight display, waterproof operation
Power Supply: 1 × 9V battery
Auto Power Off: Automatically shuts off after 10 minutes of non-use in measurement mode
International Standards: DIN EN 50081-1 VDE 0839 part 81-1: 1993-03 DIN EN 50082-2 VDE 0839 part 82-2: 1996-02
Operating Environment: Temperature 0 to 40℃; Relative Humidity 30 to 90% (no condensation)
Dimensions/Weight: 190×110×55 mm; 400g
Standard Configuration Ordering Information: ET6500 Ammonia Nitrogen Microcomputer Tester, Dual Calibration Mode, ET517611e870c618ea6e18d5993bf7ca4ecbcfb5ad3023a4e9b65db71365b9a6b6b38a, ET197621 glass cuvette, HI731318 cuvette cleaning cloth, manual, carrying case.