Insertion type electromagnetic flowmeter

by kfwli0378 on 2012-02-24 08:23:14

Electromagnetic Flow Meter, MGG Insertion Electromagnetic Flow Meter

Source: Kaifeng Wylie Flow Instrument Co., Ltd. | Release Date: October 6, 2011, 11:22:08 AM | Views: 87

I. Overview of the MGG Insertion Electromagnetic Flow Meter:

The Magne W3000 PLUS Insertion Electromagnetic Flow Meter is based on Faraday's law of electromagnetic induction and uses advanced international technology to develop a highly intelligent and reliable flow meter. It has an excellent cost-performance ratio and is widely used in large-diameter flow meter fields.

II. Features of the Insertion Electromagnetic Flow Meter:

- Measurements are not affected by changes in fluid density, viscosity, temperature, pressure, or conductivity.

- The insertion installation method of the electromagnetic flow meter ensures high reliability, with no need to dismantle the measurement pipe for sensor installation or maintenance, making it suitable for sites where water cannot be shut off long-term. It can also be installed on-site by cutting into old pipelines.

- Simple structure; the measurement tube of the insertion electromagnetic flow meter does not require lining, ensuring high reliability.

- Wide nominal diameter range, applicable to all pipeline diameters from DN300 to DN3000.

- Integrated grounding electrode for good instrument grounding.

- Sensors use advanced processing techniques, solid-state packaging, resisting vibration and preventing seepage, resulting in a long service life, providing the instrument with good measurement accuracy and stability.

III. Technical Parameters of the Insertion Electromagnetic Flow Meter:

- Nominal Diameter: DN300 to DN3000 mm

- Nominal Pressure: 1.6 MPa

- Measurement Tube Material: Carbon Steel, 304 Stainless Steel

- Sensor Measurement Head Material: PVC, ABS, Polypropylene

- Electrode Material: Molybdenum-containing Stainless Steel, Hastelloy B, Hastelloy C, Titanium

- Accuracy: ±1.5% when flow speed is 0.5 m/s, ±1.0% when full-scale flow speed > 1 m/s

- Medium Temperature: PVC, ABS: +60°C, Polypropylene: +80°C

- Environmental Temperature: -25°C to +60°C

- Relative Humidity: 5% to 95%

- Atmospheric Pressure: 86 to 106 KPa

- Straight Pipe Section Requirements: Upstream 10D, Downstream 5D

- Protection Level: IP65, optional IP68

- Connection Method: Flange Connection

- Explosion-proof Mark: ExmbⅡT4