How to operate and maintain old-fashioned diesel generators with only manual operation functions:
1. Check the airflow resistance indicator, clean the air filter when it shows red;
2. Drain the accumulated water from diesel fuel and clean the first-stage diesel filter;
3. Lubricate the fan pulley and belt tensioner bearings;
4. Check the oil level of the mechanical overspeed protection device, add oil if insufficient;
5. Check the tightening condition of main external connection bolts.
1. Cooperate with electricians for parallel load operation, check the operating conditions;
2. Cooperate with electricians to simulate tests on the performance of various safety protection devices;
3. Measure and record the shaft line and opening span;
4. Remove the inspection cover to observe the condition of the shaft and cylinder;
5. Clean the cooling system with medication (coordinate with water treatment workers);
6. Check the quality of engine oil, replace if necessary;
7. Clean the second-stage diesel filter, HDPE black-green bicolored geotextile membrane;
8. Clean the engine oil filter;
9. After every 500 hours of operation, add the following items:
A. Replace the core of the second-stage diesel filter;
B. Change the engine oil;
C. Check and tighten the cylinder head bolts and connecting rod bolts;
D. Check and adjust the valve clearance and injection timing, and make records;
E. Test and calibrate the fuel injector pressure.
1. Check the water level and oil level once a day;
2. Clean the outer surface of the unit and the machine room environment once a day.
Keywords for this site: Shandong generator, Shandong generator set, Taian generator, Taian generator set, Taian motor factory by: http://www.tachfd.cn/